Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 85
Filtrar
2.
Diabetes Res Clin Pract ; 209: 111597, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38417535

RESUMO

AIMS: To evaluate real-world outcomes in people with Type 1 Diabetes (PwT1D) initiated on Omnipod DASH® Insulin Management System. METHODS: Anonymized clinical data were submitted to a secure web-based tool within the National Health Service network. Hemoglobin A1c (HbA1c), sensor-derived glucometrics, total daily dose of insulin (TDD), and patient-reported outcome changes between baseline and follow-up were assessed. Individuals were classified to "new-to-pump" (switched from multiple daily injections) and "established-on-pump" (switched from a tethered insulin pump) groups. RESULTS: 276 individuals from 11 centers [66.7 % female; 92 % White British; median age 41 years (IQR 20-50); diabetes duration 20 years (IQR 11-31); 49.3 % within "new-to-pump" group] were included. Baseline HbA1c was 8.0 ± 1.3 % (64 ± 14 mmol/mol). At follow-up [3 years (IQR 1.5-3.2)], HbA1c reduced by 0.3 % [(3 mmol/mol); p = 0.002] across the total population, 0.4 % [(5 mmol/mol); p = 0.001] in those "new-to-pump" and remained unchanged in those "established-on-pump". TDD decreased in the "new-to-pump" cohort (baseline:44.9 ± 21.0units vs follow-up:38.1 ± 15.4units, p = 0.002). Of those asked, 141/143 (98.6 %) stated Omnipod DASH had a positive impact on quality of life. CONCLUSIONS: Omnipod DASH was associated with improvements in HbA1c in PwT1D "new-to-pump" and maintained previous HbA1c levels in those "established-on-pump". User satisfaction in all groups and TDD reduction in those "new-to-pump" were reported.


Assuntos
Diabetes Mellitus Tipo 1 , Humanos , Feminino , Adulto , Masculino , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Hemoglobinas Glicadas , Qualidade de Vida , Medicina Estatal , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Glicemia
3.
Artigo em Inglês | MEDLINE | ID: mdl-38315506

RESUMO

Objective: To evaluate postprandial glucose control when applying (1) faster-acting insulin aspart (Fiasp) compared to insulin aspart and (2) ultra-rapid insulin lispro (Lyumjev) compared to insulin lispro using the CamAPS FX hybrid closed-loop algorithm. Research Design and Methods: We undertook a secondary analysis of postprandial glucose excursions from two double-blind, randomized, crossover hybrid closed-loop studies contrasting Fiasp to standard insulin aspart, and Lyumjev to standard insulin lispro. Endpoints included incremental area under curve (iAUC)-2h, iAUC-4h, 4 h postprandial time in target range, time above range, and time below range. It was approved by independent research ethics committees. Results: Two trials with 8 weeks of data from 51 adults with type 1 diabetes were analyzed and 7137 eligible meals were included. During Lyumjev compared with insulin lispro, iAUC-2h and iAUC-4h were significantly decreased following breakfast (mean difference 92 mmol/L per 2 h (95% confidence interval [CI]: 56 to 127); P < 0.001 and 151 mmol/L per 4 h (95% CI: 74 to 229); P < 0.001, respectively) and the evening meal (P < 0.001 and P = 0.011, respectively). Mean time in target range (3.9-10.0 mmol/L) for 4 h postprandially significantly increased during Lyumjev with a mean difference of 6.7 percentage points (95% CI: 3.3 to 10) and 5.7 percentage points (95% CI: 1.4 to 9.9) for breakfast and evening meal, respectively. In contrast, there were no significant differences in iAUC-2h, iAUC-4h, and the other measures of postprandial glucose control between insulin aspart and Fiasp during breakfast, lunch, and evening meal (P > 0.05). Conclusion: The use of Lyumjev with CamAPS FX closed-loop system improved postprandial glucose excursions compared with insulin lispro, while the use of Fiasp did not provide any advantage compared with insulin aspart. Clinical Trial Registration numbers: NCT04055480, NCT05257460.

4.
Diabet Med ; 41(3): e15249, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37897112

RESUMO

AIMS: The FLASH-UK trial showed lower HbA1c with intermittently scanned continuous glucose monitoring (isCGM), as compared with self monitoring of blood glucose (SMBG), in adults with type 1 diabetes and HbA1c ≥58 mmol/mol (≥7.5%). Here, we present results from the pre-specified subgroup analysis for the 24-week HbA1c (primary outcome) and selected sensor-based secondary outcomes. METHODS: This was a multi-centre, parallel-design, randomised controlled trial. The difference in treatment effect between subgroups (baseline HbA1c [≤75 vs. >75 mmol/mol] [≤9.0 vs >9.0%], treatment modality [pump vs injections], prior participation in structured education, age, educational level, impaired awareness of hypoglycaemia, deprivation index quintile sex, ethnic group and Patient Health Questionnaire-9 [PHQ-9] detected depression category) were evaluated. RESULTS: One hundred fifty-six participants (females 44%, mean [SD] baseline HbA1c 71 [9] mmol/mol 8.6 [0.8%], age 44 [15]) were randomly assigned, in a 1:1 ratio to isCGM (n = 78) or SMBG (n = 78). The mean (SD) baseline HbA1c (%) was 8.7 (0.9) in the isCGM group and 8.5 (0.8) in the SMBG group, lowering to 7.9 (0.8) versus 8.3 (0.9), respectively, at 24 weeks (adjusted mean difference -0.5, 95% confidence interval [CI] -0.7 to -0.3; p < 0.001]. For HbA1c, there was no impact of treatment modality, prior participation in structured education, deprivation index quintile, sex or baseline depression category. The between-group difference in HbA1c was larger for younger people (a reduction of 2.7 [95% CI 0.3-5.0; p = 0.028] mmol/mol for every additional 15 years of age). Those with HbA1c 76-97 mmol/mol (>9.0%-11.0%) had a marginally non-significant higher reduction in HbA1c of 8.4 mmol/mol (3.3-13.5) compared to 3.1 (0.3-6.0) in those with HbA1c 58-75 mmol/mol (p = 0.08). For 'Time in range' (% 3.9-10 mmol/L), the difference was larger for those with at least a bachelor's degree. For 'Time below range' (% <3.9 mmol/L), the difference was larger for those using injections, older people and those with less than bachelor's degree. CONCLUSIONS: Intermittently scanned continuous glucose monitoring is generally effective across a range of baseline characteristics.


Assuntos
Diabetes Mellitus Tipo 1 , Adulto , Feminino , Humanos , Idoso , Glicemia/análise , Hemoglobinas Glicadas , Automonitorização da Glicemia/métodos , Reino Unido , Hipoglicemiantes/uso terapêutico
6.
Diabet Med ; 41(3): e15232, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37750427

RESUMO

OBJECTIVE: We previously showed that intermittently scanned continuous glucose monitoring (isCGM) reduces HbA1c at 24 weeks compared with self-monitoring of blood glucose with finger pricking (SMBG) in adults with type 1 diabetes and high HbA1c levels (58-97 mmol/mol [7.5%-11%]). We aim to assess the economic impact of isCGM compared with SMBG. METHODS: Participant-level baseline and follow-up health status (EQ-5D-5L) and within-trial healthcare resource-use data were collected. Quality-adjusted life-years (QALYs) were derived at 24 weeks, adjusting for baseline EQ-5D-5L. Participant-level costs were generated. Using the IQVIA CORE Diabetes Model, economic analysis was performed from the National Health Service perspective over a lifetime horizon, discounted at 3.5%. RESULTS: Within-trial EQ-5D-5L showed non-significant adjusted incremental QALY gain of 0.006 (95% CI: -0.007 to 0.019) for isCGM compared with SMBG and an adjusted cost increase of £548 (95% CI: 381-714) per participant. The lifetime projected incremental cost (95% CI) of isCGM was £1954 (-5108 to 8904) with an incremental QALY (95% CI) gain of 0.436 (0.195-0.652) resulting in an incremental cost-per-QALY of £4477. In all subgroups, isCGM had an incremental cost-per-QALY better than £20,000 compared with SMBG; for people with baseline HbA1c >75 mmol/mol (9.0%), it was cost-saving. Sensitivity analysis suggested that isCGM remains cost-effective if its effectiveness lasts for at least 7 years. CONCLUSION: While isCGM is associated with increased short-term costs, compared with SMBG, its benefits in lowering HbA1c will lead to sufficient long-term health-gains and cost-savings to justify costs, so long as the effect lasts into the medium term.


Assuntos
Diabetes Mellitus Tipo 1 , Adulto , Humanos , Diabetes Mellitus Tipo 1/terapia , Glicemia , Análise Custo-Benefício , Automonitorização da Glicemia/métodos , Hemoglobinas Glicadas , Medicina Estatal , Inglaterra/epidemiologia , Hipoglicemiantes
7.
Diabetes Care ; 46(10): 1831-1838, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37566697

RESUMO

OBJECTIVE: We explored longitudinal changes associated with switching to hybrid closed-loop (HCL) insulin delivery systems in adults with type 1 diabetes and elevated HbA1c levels despite the use of intermittently scanned continuous glucose monitoring (isCGM) and insulin pump therapy. RESEARCH DESIGN AND METHODS: We undertook a pragmatic, preplanned observational study of participants included in the National Health Service England closed-loop pilot. Adults using isCGM and insulin pump across 31 diabetes centers in England with an HbA1c ≥8.5% who were willing to commence HCL therapy were included. Outcomes included change in HbA1c, sensor glucometrics, diabetes distress score, Gold score (hypoglycemia awareness), acute event rates, and user opinion of HCL. RESULTS: In total, 570 HCL users were included (median age 40 [IQR 29-50] years, 67% female, and 85% White). Mean baseline HbA1c was 9.4 ± 0.9% (78.9 ± 9.1 mmol/mol) with a median follow-up of 5.1 (IQR 3.9-6.6) months. Of 520 users continuing HCL at follow-up, mean adjusted HbA1c reduced by 1.7% (95% CI 1.5, 1.8; P < 0.0001) (18.1 mmol/mol [95% CI 16.6, 19.6]; P < 0.0001). Time in range (70-180 mg/dL) increased from 34.2 to 61.9% (P < 0.001). Individuals with HbA1c of ≤58 mmol/mol rose from 0 to 39.4% (P < 0.0001), and those achieving ≥70% glucose time in range and <4% time below range increased from 0.8 to 28.2% (P < 0.0001). Almost all participants rated HCL therapy as having a positive impact on quality of life (94.7% [540 of 570]). CONCLUSIONS: Use of HCL is associated with improvements in HbA1c, time in range, hypoglycemia, and diabetes-related distress and quality of life in people with type 1 diabetes in the real world.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Humanos , Adulto , Feminino , Masculino , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Hemoglobinas Glicadas , Glicemia , Automonitorização da Glicemia , Qualidade de Vida , Medicina Estatal , Insulina , Sistemas de Infusão de Insulina
8.
Diabetes Technol Ther ; 25(7): 485-491, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37229591

RESUMO

Objective: We aimed to assess whether percentage of time spent in hypoglycemia during closed-loop insulin delivery differs by age group and time of day. Methods: We retrospectively analyzed data from hybrid closed-loop studies involving young children (2-7 years), children and adolescents (8-18 years), adults (19-59 years), and older adults (≥60 years) with type 1 diabetes. Main outcome was time spent in hypoglycemia <3.9 mmol/L (<70 mg/dL). Eight weeks of data for 88 participants were analyzed. Results: Median time spent in hypoglycemia over the 24-h period was highest in children and adolescents (4.4% [interquartile range 2.4-5.0]) and very young children (4.0% [3.4-5.2]), followed by adults (2.7% [1.7-4.0]), and older adults (1.8% [1.2-2.2]); P < 0.001 for difference between age groups. Time spent in hypoglycemia during nighttime (midnight-05:59) was lower than during daytime (06:00-23:59) across all age groups. Conclusion: Time in hypoglycemia was highest in the pediatric age group during closed-loop insulin delivery. Hypoglycemia burden was lowest overnight across all age groups.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Adolescente , Idoso , Criança , Pré-Escolar , Humanos , Glicemia , Estudos Cross-Over , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemia/induzido quimicamente , Hipoglicemia/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Insulina/efeitos adversos , Sistemas de Infusão de Insulina , Insulina Regular Humana/uso terapêutico , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem , Adulto , Pessoa de Meia-Idade
9.
Diabet Med ; 40(11): e15124, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37099713
10.
Eur J Endocrinol ; 188(4): R73-R87, 2023 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-36929837

RESUMO

Successful pancreas or islet transplantation is currently the only cure for type 1 diabetes mellitus. Since the first pancreas transplant in 1966, there have been various refinements of surgical technique along with improved immunosuppressive regimens, resulting in significantly improved outcomes, with contemporary research into graft monitoring and newer biomarkers, potentially lengthening graft survival rates further. Patients with insulin-dependent diabetes mellitus who are eligible for pancreas or islet transplantation represent a select group, the tip of the iceberg for a significant global diabetes disease burden. In the last 50 years, there have been quantum advances in alternative technologies in diabetes therapy, both experimental and translational. Further development and improved access are required to treat the larger proportion of people suffering from diabetes. Emerging stem cell therapy is still experimental whereas alternatives including automated insulin delivery systems and islet cell transplantation are already used in some countries. Whilst automated insulin delivery systems have increased in efficacy, they still do not achieve the near physiological control of blood sugar, which can be achieved by successful pancreas or islet transplantation. This state-of-the-art review provides a summary of pancreas and islet transplantation to its current place in diabetes therapy, along with alternative and future therapies, including the obstacles associated with the dissemination of these new therapies. With the advent of these modern cellular and technological advances, this review addresses the question: are we entering an era where whole organ pancreas transplantation could be replaced entirely by modern technological advances in diabetes therapy?


Assuntos
Diabetes Mellitus Tipo 1 , Insulinas , Transplante das Ilhotas Pancreáticas , Transplante de Pâncreas , Humanos , Transplante de Pâncreas/métodos , Transplante das Ilhotas Pancreáticas/métodos , Diabetes Mellitus Tipo 1/terapia , Imunossupressores
13.
Diabetes Obes Metab ; 25(4): 916-939, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36585365

RESUMO

The National Institute for Clinical Excellence updated guidance for continuous glucose monitoring (CGM) in 2022, recommending that CGM be available to all people living with type 1 diabetes. Manufacturers can trade in the UK with Conformité Européenne (CE) marking without an initial national assessment. The regulatory process for CGM CE marking, in contrast to the Food and Drug Administration (FDA) and Australian Therapeutic Goods Administration (TGA) process, is described. Manufacturers operating in the UK provided clinical accuracy studies submitted for CE marking. Critical appraisal of the studies shows several CGM devices have CE marking for wide-ranging indications beyond available data, unlike FDA and TGA approval. The FDA and TGA use tighter controls, requiring comprehensive product-specific clinical data evaluation. In 2018, the FDA published the integrated CGM (iCGM) criteria permitting interoperability. Applying the iCGM criteria to clinical data provided by manufacturers trading in the UK identified several study protocols that minimized glucose variability, thereby improving CGM accuracy on all metrics. These results do not translate into real-life performance. Furthermore, for many CGM devices available in the UK, accuracy reported in the hypoglycaemic range is below iCGM standards, or measurement is absent. We offer a framework to evaluate CGM accuracy studies critically. The review concludes that FDA- and TGA-approved indications match the available clinical data, whereas CE marking indications can have discrepancies. The UK can bolster regulation with UK Conformity Assessed marking from January 2025. However, balanced regulation is needed to ensure innovation and timely technological access are not hindered.


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Estados Unidos , Humanos , Automonitorização da Glicemia , United States Food and Drug Administration , Austrália , Diabetes Mellitus Tipo 1/tratamento farmacológico
15.
J Diabetes Sci Technol ; : 19322968221141924, 2022 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-36475908

RESUMO

OBJECTIVE: Many hybrid closed-loop (HCL) systems struggle to manage unusually high glucose levels as experienced with intercurrent illness or pre-menstrually. Manual correction boluses may be needed, increasing hypoglycemia risk with overcorrection. The Cambridge HCL system includes a user-initiated algorithm intensification mode ("Boost"), activation of which increases automated insulin delivery by approximately 35%, while remaining glucose-responsive. In this analysis, we assessed the safety of "Boost" mode. METHODS: We retrospectively analyzed data from closed-loop studies involving young children (1-7 years, n = 24), children and adolescents (10-17 years, n = 19), adults (≥24 years, n = 13), and older adults (≥60 years, n = 20) with type 1 diabetes. Outcomes were calculated per participant for days with ≥30 minutes of "Boost" use versus days with no "Boost" use. Participants with <10 "Boost" days were excluded. The main outcome was time spent in hypoglycemia <70 and <54 mg/dL. RESULTS: Eight weeks of data for 76 participants were analyzed. There was no difference in time spent <70 and <54 mg/dL between "Boost" days and "non-Boost" days; mean difference: -0.10% (95% confidence interval [CI] -0.28 to 0.07; P = .249) time <70 mg/dL, and 0.03 (-0.04 to 0.09; P = .416) time < 54 mg/dL. Time in significant hyperglycemia >300 mg/dL was 1.39 percentage points (1.01 to 1.77; P < .001) higher on "Boost" days, with higher mean glucose and lower time in target range (P < .001). CONCLUSIONS: Use of an algorithm intensification mode in HCL therapy is safe across all age groups with type 1 diabetes. The higher time in hyperglycemia observed on "Boost" days suggests that users are more likely to use algorithm intensification on days with extreme hyperglycemic excursions.

16.
J Diabetes Sci Technol ; : 19322968221145184, 2022 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-36540007

RESUMO

BACKGROUND: CamAPS FX is a hybrid closed-loop smartphone app used to manage type one diabetes. The closed-loop algorithm has a default target glucose of 5.8 mmol/L (104.5 mg/dL), but users can select personal glucose targets (adjustable between 4.4 mmol/L and 11.0 mmol/L [79 mg/dL and 198 mg/dL, respectively]). METHOD: In this post-hoc analysis, we evaluated the impact of personal glucose targets on glycemic control using data from participants in five randomized controlled trials. RESULTS: Personal glucose targets were widely used, with 20.3% of all days in the data set having a target outside the default target bin (5.5-6.0 mmol/L [99-108 mg/dL]). Personal glucose targets >6.5 mmol/L (117 mg/dL) were associated with significantly less time in target range (3.9-10.0 mmol/L [70-180 mg/dL]; 6.5-7.0 mmol/L [117-126 mg/dL]: mean difference = -3.2 percentage points [95% CI: -5.3 to -1.2; P < .001]; 7.0-7.5 mmol/L [126-135 mg/dL]: -10.8 percentage points [95% CI: -14.1 to -7.6; P < .001]). Personal targets >6.5 mmol/L (117 mg/dL) were associated with significantly lower time (<3.9 mmol/L [<70 mg/dL]; 6.5-7.0 mmol/L [117-126 mg/dL]: -1.85 percentage points [95% CI: -2.37 to -1.34; P < .001]; 7.0-7.5 mmol/L [126-135 mg/dL]: -2.68 percentage points [95% CI: -3.49 to -1.86; P < .001]). CONCLUSIONS: Discrete study populations showed differences in glucose control when applying similar personal targets.

17.
N Engl J Med ; 387(16): 1477-1487, 2022 10 20.
Artigo em Inglês | MEDLINE | ID: mdl-36198143

RESUMO

BACKGROUND: In persons with type 1 diabetes and high glycated hemoglobin levels, the benefits of intermittently scanned continuous glucose monitoring with optional alarms for high and low blood glucose levels are uncertain. METHODS: In a parallel-group, multicenter, randomized, controlled trial involving participants with type 1 diabetes and glycated hemoglobin levels between 7.5% and 11.0%, we investigated the efficacy of intermittently scanned continuous glucose monitoring as compared with participant monitoring of blood glucose levels with fingerstick testing. The primary outcome was the glycated hemoglobin level at 24 weeks, analyzed according to the intention-to-treat principle. Key secondary outcomes included sensor data, participant-reported outcome measures, and safety. RESULTS: A total of 156 participants were randomly assigned, in a 1:1 ratio, to undergo intermittently scanned continuous glucose monitoring (the intervention group, 78 participants) or to monitor their own blood glucose levels with fingerstick testing (the usual-care group, 78 participants). At baseline, the mean (±SD) age of the participants was 44±15 years, and the mean duration of diabetes was 21±13 years; 44% of the participants were women. The mean baseline glycated hemoglobin level was 8.7±0.9% in the intervention group and 8.5±0.8% in the usual-care group; these levels decreased to 7.9±0.8% and 8.3±0.9%, respectively, at 24 weeks (adjusted mean between-group difference, -0.5 percentage points; 95% confidence interval [CI], -0.7 to -0.3; P<0.001). The time per day that the glucose level was in the target range was 9.0 percentage points (95% CI, 4.7 to 13.3) higher or 130 minutes (95% CI, 68 to 192) longer in the intervention group than in the usual-care group, and the time spent in a hypoglycemic state (blood glucose level, <70 mg per deciliter [<3.9 mmol per liter]) was 3.0 percentage points (95% CI, 1.4 to 4.5) lower or 43 minutes (95% CI, 20 to 65) shorter in the intervention group. Two participants in the usual-care group had an episode of severe hypoglycemia, and 1 participant in the intervention group had a skin reaction to the sensor. CONCLUSIONS: Among participants with type 1 diabetes and high glycated hemoglobin levels, the use of intermittently scanned continuous glucose monitoring with optional alarms for high and low blood glucose levels resulted in significantly lower glycated hemoglobin levels than levels monitored by fingerstick testing. (Funded by Diabetes UK and others; FLASH-UK ClinicalTrials.gov number, NCT03815006.).


Assuntos
Automonitorização da Glicemia , Diabetes Mellitus Tipo 1 , Hemoglobinas Glicadas , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Glicemia/análise , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hemoglobinas Glicadas/análise , Hipoglicemia/induzido quimicamente , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem
19.
Lancet Healthy Longev ; 3(3): e135-e142, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35359882

RESUMO

Background: Older adults with type 1 diabetes have distinct characteristics that can make optimising glycaemic control challenging. We sought to test our hypothesis that hybrid closed-loop glucose control is safe and more effective than sensor-augmented pump (SAP) therapy in older adults with type 1 diabetes. Methods: In an open-label, multicentre, multinational (UK and Austria), randomised, crossover study, adults aged 60 years and older with type 1 diabetes using insulin pump therapy underwent two 16-week periods comparing hybrid closed-loop (CamAPS FX, CamDiab, Cambridge, UK) and SAP therapy in random order. Block randomisation by means of central randomisation software to one of two treatment sequences was stratified by centre. The primary endpoint was the proportion of time sensor glucose was in target range between 3·9 and 10·0 mmol/L. Analysis for the primary endpoint and adverse events was by intention-to-treat. The study has completed and is registered at ClinicalTrials.gov NCT04025762. Findings: 38 participants were enrolled. One participant withdrew during run-in because of difficulties with the study pump infusion sets. 37 participants (median [IQR] age 68 [63-70] years, mean [SD] baseline glycated haemoglobin [HbA1c]; 7·4% [0·9%]; 57 [10] mmol/mol) were randomly assigned between Sept 4, 2019, and Oct 2, 2020. The proportion of time with glucose between 3·9 and 10·0 mmol/L was significantly higher in the closed-loop group compared to the SAP group (79·9% [SD 7·9] vs 71·4% [13·2], difference 8·6 percentage points [95% CI 6·3 to 11·0]; p<0·0001). Two severe hypoglycaemia events occurred during the SAP period. There were two non-treatment related serious adverse events: cardiac arrest from pulmonary embolism associated with COVID-19 during the SAP period resulting in death, and a hospital presentation for parenteral hydrocortisone because of COVID-19 in a participant with adrenal insufficiency during the run-in period. Interpretation: Hybrid closed-loop insulin delivery is safe and achieves superior glycaemic control to SAP therapy in older adults with long duration of type 1 diabetes. Importantly this was achieved without increasing the risk of hypoglycaemia in this population with risk factors for severe hypoglycaemia. This suggests that hybrid closed-loop therapy is a clinically important treatment option for older adults with type 1 diabetes.


Assuntos
COVID-19 , Diabetes Mellitus Tipo 1 , Hipoglicemia , Idoso , Glicemia , Estudos Cross-Over , Glucose , Humanos , Hipoglicemiantes , Insulina , Sistemas de Infusão de Insulina , Pessoa de Meia-Idade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...